  • Additional System Characteristics

    Allowable Deflection: L/240
    ci Material: Mineral wool
    Available ci R-value max R58
    Typical wall thickness at minimum R-Value 2" (R0 or 4.3)
    Typical wall thickness at maximum R-Value 15-3/4" (R58)
    Construction Type I, II, III, IV, V
    Code Reports Intertek Listing 79917
    System NFPA 285 and Fire Resistance Compliance ASTM E2652 non-combustible system with Sto AWRB and 2" mineral wool complies with NFPA 285
    Approximate weight 3.2-4.0 lbs/sf
    Service life, years >50 years
    Sustainability
    Air and Moisture Barrier System StoGuard vapor permeable or impermeable system
    Defined drainage plane Yes
    Height Restrictions May apply depending on construction type and wind load.
    Fortification Layer:
    Fireblocking Available with Sto Fireblocking
    Cost $$-$$$